DUCTLESS AND DUCTED
MULTIZONE HEAT PUMPS
HEAT+ | Up to 23 SEER | -25°C & -30°C
Multi-Moov
Versatile comfort for every room.
Versatile and functional, a Multi-Moov system provides customizable comfort in every room of your home. Ideal for large homes, Moovair multizone systems allow independent control of up to five indoor zones from a single outdoor unit. Choose from a selection of four indoor unit types, depending on need, style and home layout.
Ducted: The compact ducted unit installation flexibility of horizontal or vertical orientation means this unit can be adapted to a multitude of different installation locations. The concealed ducted unit is the ideal way to achieve an exceptionally clean and discrete finish.
Cassette: Designed to fit in a suspended ceiling or between ceiling joists, this unit is ideal for more confined spaces such as corridors or split levels because it is equipped with four-way directional shutters ensuring maximum air dispersion to achieve a balanced temperature throughout the area.
Floor console: For every home design, there’s a unique heating and cooling solution. The design of these units is like that of a wall convector. With limited wall space and easy accessibility for maintenance and cleaning, a floor console is an ideal choice.
Get cozy with the leader in its category.
Moovair multizone systems have established themselves in the market because of their superior performance ensuring energy savings without compromising comfort.
The Moovair Effect
Backed by 70 years of HVAC experience, Moovair was developed with the harsh Canadian climate in mind. We created reliable, energy-efficient products that take care of the environment as well as your comfort and peace of mind because your home is at the heart of your well-being. That is the Moovair Effect.
DOWNLOAD BROCHURE
To explore more, download the Multi-Moov Series brochure.
Moovair dealers are supported by The Master Group, Canada’s largest independently Canadian owned HVAC-R distributor. Through its 70 year history, The Master Group distinguishes itself for its extensive inventory, technical expertise, and exceptional customer service.
The comfort and pleasure of staying home
Built to last, Moovair heat pumps are covered by one of the best warranty programs in the industry: 10-year limited parts and compressor warranty. Optional labor coverage of 5 and 10 years are also available.
Documents
Technical specifications
HEAT PUMP SYSTEM | 18,000* BTU | 27,000* BTU | 36,000 BTU | 48,000* BTU | |
Outdoor model | DMA18HOM23230X2 | DMA27HOM23230X2 | DMA36HOM23230X2 | DMA48HOM23230X2 | |
Indoor model | According to combinations | According to combinations | According to combinations | According to combinations | |
Power supply V/Ph/Hz | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | |
Cooling | Capacity BTU/h | 18,000 | 28,000 | 36,000 | 48,000 |
Min. – max. cooling BTU/h | 5,650~22,000 | 9,838~30,438 | 8,209~40,555 | 19,000~50,000 | |
EER BTU/Wh | 13 | 12.5 | 11.5 | 12.5 | |
SEER BTU/Wh | 23 | 23.8 | 23 | 22.4 | |
Heating | Capacity BTU/h | 19,000 | 28,000 | 37,000 | 48,000 |
Min. – max. heating BTU/h | 5,050~24,400 | 8,218~31,000 | 8 ,008~44,632 | 12,500~52,000 | |
COP W/W | 3.9 | 3.73 | 3.61 | 3.6 | |
HSPF (Region 4) BTU/Wh | 10.6 | 10.5 | 11.3 | 11 | |
Max. fuse (A) | 25 | 30 | 40 | 60 | |
Compressor type | rotary | rotary | rotary | rotary | |
Outdoor noise level dB(A) | 58.5 | 61 | 63 | 62 | |
Outdoor model | Width x Depth x Height mm | 890×342×673 | 946×410×810 | 946×410×810 | 952×415×1333 |
Width x Depth x Height in | 35.04×13.46×26.5 | 37.24×16.14×31.89 | 37.24×16.14×31.89 | 37.48×16.34×52.48 | |
Net/Gross weight kg | 45.5/49.3 | 63.4/68.3 | 76.7/82.3 | 102.3/116.4 | |
Net/Gross weight lbs | 100.31/108.69 | 139.77/150.57 | 169.09/181.44 | 225.53/256.62 | |
Refrigerant precharge in | 49 | 74 | 98 | 123 | |
Refrigerant piping | Liquid side, Gas side in | 2x 1/4″, 2x 3/8″ | 3x 1/4″, 3x 3/8″ | 4×1/4″, 3×3/8” + 1×1/2” | 5x 1/4”, 3×3/8” + 2×1/2” |
Max. length for all rooms m (ft) | 40 (131) | 60 (197) | 80 (262) | 80 (262) | |
Max. length for one indoor unit m (ft) | 25 (82) | 30 (98) | 35 (115) | 35 (115) | |
Max. height difference between indoor and outdoor unit m (ft) | 15 (49) | 15 (49) | 15 (49) | 15 (49) | |
Max. height difference between indoor units m (ft) | 10 (33) | 10 (33) | 10 (33) | 10 (33) | |
Thermostat type | see indoor unit | see indoor unit | see indoor unit | see indoor unit | |
Operating temperature range | Cooling °C (ºF) | -25~50 (-13~122) | -25–50 (-13–122) | -25–50 (-13–122) | -25–50 (-13–122) |
Heating °C (ºF) | -25~24 (-13~75) | -25~24 (-13~75) | -25~24 (-13~75) | -25~24 (-13~75) |
*EnergyStar
HEAT PUMP SYSTEM | 18,000* BTU | 27,000* BTU | 36,000* BTU | 48,000 BTU | |
Outdoor model | DMA18HOM25230X3 | DMA27HOM25230X3 | DMA36HOM25230X3 | DMA48HOM25230X3 | |
Indoor model | According to combinations | According to combinations | According to combinations | According to combinations | |
Power supply V/Ph/Hz | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | |
Cooling | Capacity BTU/h | 19,000 | 28,000 | 36,000 | 48,000 |
Min. – max. cooling BTU/h | 5,500~25,000 | 7,995~32,826 | 17,900~42,000 | 19,300~51,000 | |
EER BTU/Wh | 12.5 | 12.5 | 13.6 | 11.6 | |
SEER BTU/Wh | 22 | 22.5 | 21.8 | 21.5 | |
Heating | Capacity BTU/h | 20,000 | 28,000 | 36,500 | 49,000 |
Min. – max. heating BTU/h | 8,100~29,700 | 5,035~38,712 | 12,500~49,000 | 11,500~58,000 | |
COP W/W | 3.4 | 3.66 | 3.85 | 3.59 | |
HSPF (Region 4) BTU/Wh | 10.2 | 11.3 | 11 | 11 | |
Max. fuse (A) | 25 | 40 | 60 | 60 | |
Compressor type | Rotary | Rotary | Rotary | Rotary | |
Outdoor noise level dB(A) | 61 | 63 | 62 | 65 | |
Outdoor model | Width x Depth x Height mm | 946×410×810 | 946×410×810 | 952×415×1333 | 952×415×1333 |
Width x Depth x Height in | 37.24×16.14×31.89 | 37.24×16.14×31.89 | 37.48×16.34×52.48 | 37.48×16.34×52.48 | |
Net/Gross weight kg | 62.7/67.6 | 76.2/81.5 | 101.2/115.2 | 108.1/122.4 | |
Net/Gross weight lbs | 138.23/149.03 | 167.99/179.67 | 223.11/253.97 | 238.32/269.84 | |
Refrigerant precharge in | 49 | 74 | 98 | 123 | |
Refrigerant piping | Liquid side, Gas side in | 2x 1/4″, 2x 3/8″ | 3x 1/4″, 3x 3/8″ | 4x 1/4″, 3×3/8” + 1×1/2” | 5×1/4″, 3×3/8” + 2×1/2” |
Max. length for all rooms m (ft) | 40 (131) | 60 (197) | 80 (262) | 80 (262) | |
Max. length for one indoor unit m (ft) | 25 (82) | 30 (98) | 35 (115) | 35 (115) | |
Max. height difference between indoor and outdoor unit m (ft) | 15 (49) | 15 (49) | 15 (49) | 15 (49) | |
Max. height difference between indoor units m (ft) | 10 (33) | 10 (33) | 10 (33) | 10 (33) | |
Thermostat type | See indoor unit | See indoor unit | See indoor unit | See indoor unit | |
Operating temperature range | Cooling °C (ºF) | -30~50 (-22~122) | -30~50 (-22~122) | -30~50 (-22~122) | -30~50 (-22~122) |
Heating °C (ºF) | -30~24 (-22~75) | -30~24 (-22~75) | -30~24 (-22~75) | -30~24 (-22~75) |
*EnergyStar
HEAT PUMP SYSTEM | 6,000 BTU | 9,000 BTU | 12,000 BTU | 18,000 BTU | 24,000 BTU | |
Indoor model | DMA06HIW25230E8 | DMA09HIW25230E8 | DMA12HIW25230E8 | DMA18HIW25230E8 | DMA24HIW25230E8 | |
Power supply V/Ph/Hz | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | |
Liquid side/Gas side mm (in) | 6.35/9.52 (1/4’’/3/8’’) | 6.35/9.52 (1/4’’/3/8’’) | 6.35/12.7 (1/4’’/1/2’’) | 6.35/12.7 (1/4’’/1/2’’) | 9.52/15.9 (3/8’’/5/8’’) | |
Indoor air flow (Hi/Med/Low) CFM | 317.65/217.65/167.65 | 335.29/229.41/176.47 | 335.29/229.41/176.47 | 523.53/376.47/305.88 | 611.18/414.12/318.82 | |
Indoor noise level (Hi/Med/Low) dB(A) | 36/32/23 | 38/33.5/23.5 | 38/33.5/23.5 | 46/42/24 | 46/39/34 | |
Indoor model | Width x Depth x Height in | 31.3×8.86×11.61 | 31.3×8.86×11.61 | 31.3×8.86×11.61 | 37.99×9.41×12.56 | 44.88×10.83×14.57 |
Net/Gross weight lbs | 22.71/28.88 | 22.71/28.88 | 22.93/28.88 | 27.12/35.71 | 43.65/54.89 | |
Application area sq. ft. | 86.11~129.17 | 129.17~193.75 | 172.22~247.57 | 258.33~376.74 | 344.44~505.90 |
HEAT PUMP SYSTEM | 9,000 BTU | 12,000 BTU | 18,000 BTU | 24,000 BTU | |
Indoor model | DUA09HIDU230X5 | DUA12HIDU230X5 | DUA18HIDU230X5 | DUA24HIDU230X5 | |
Power supply V/Ph/Hz | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | |
Liquid side/Gas side mm (in) | 6.35/9.52 (1/4’’/3/8’’) | 6.35/12.7 (1/4’’/1/2’’) | 6.35/12.7 (1/4’’/1/2’’) | 9.52/15.9 (3/8’’/5/8’’) | |
Indoor air flow (Hi/Med/Low) CFM | 352.94/282.35/176.47 | 352.94/282.35/176.47 | 529.41/450/370.59 | 775.47/693.06/434.88 | |
Indoor noise level (Hi/Med/Low) dB(A) | 33/30.5/27 | 40/31.5/26.5 | 40/37.5/35 | 44/40/35.5 | |
Indoor model | Width x Depth x Height in | 27.56×19.92×7.87 | 27.56×19.92×7.87 | 34.65×28.53×8.27 | 43×30×10 |
Net/Gross weight lbs | 39.02/48.28 | 39.24/48.5 | 55.34/67.02 | 90.39/105.82 | |
Application area sq. ft. | 129.17~193.75 | 172.22~247.57 | 236.81~344.44 | 344.44~505.90 |
HEAT PUMP SYSTEM | 9,000 BTU | 12,000 BTU | 18,000 BTU | 24,000 BTU | |
Indoor model | DUA09HICU230X5 | DUA12HICU230X5 | DUA18HICU230X5 | DUA24HICU230X5 | |
Power supply V/Ph/Hz | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | 208–230/1/60 | |
Liquid side/Gas side mm (in) | 6.35/9.52 (1/4’’/3/8’’) | 6.35/12.7 (1/4’’/1/2’’) | 6.35/12.7 (1/4’’/1/2’’) | 9.52/15.9(3/8’’/5/8’’) | |
Indoor air flow (Hi/Med/Low) CFM | 352.94/305.88/270.59 | 379/309/261 | 562.35/485.29/438.82 | 705.88/635.29/547.06 | |
Indoor noise level (Hi/Med/Low) dB(A) | 39.5/36/32.5 | 40.5/35.5/31.5 | 43.5/38.5/35.5 | 48/45.5/43 | |
Indoor model | Width x Depth x Height in | 22.44×22.44×10.24 | 22.44×22.44×10.24 | 22.44×22.44×10.24 | 32.68×32.68×8.07 |
Net/Gross weight lbs | 31.97/38.14 | 35.27/41.01 | 35.71/46.96 | 47.18/55.34 | |
Application area sq. ft. | 129.17~193.75 | 172.22~247.57 | 226.04~333.68 | 344.44~505.9 |
HEAT PUMP SYSTEM | 12,000 BTU | |
Indoor model | DUA12HIFU230E5 | |
Power supply V/Ph/Hz | 208–230/1/60 | |
Liquid side/Gas side mm (in) | 6.35/12.7 (1/4’’/1/2’’) | |
Indoor air flow (Hi/Med/Low) CFM | 364.71/318.24/247.65 | |
Indoor noise level (Hi/Med/Low) dB(A) | 43/39/33 | |
Indoor model | Width x Depth x Height in | 27.56×23.62×8.27 |
Net/Gross weight lbs | 32.63/41.01 | |