Country/Language: Canada (EN)

Matched coil add-on system

HEAT+ | Up to 16.8 SEER2 | -30°C*

Central-Moov

Home comfort is our priority

Moovair products are designed for the Canadian climate with your comfort and well-being in mind. A Central-Moov heat pump system maintains the serenity of your home by keeping you cozy all year round in whisper-quiet, energy efficient comfort.

Whisper-quiet operation

Home comfort is best enjoyed in peaceful, serene surroundings, whether inside or out. Central-Moov provides whisper-quiet performance inside, while the side discharge design of the outdoor unit provides ultra-quiet operation as low as 58 dB(A) outside allowing you to enjoy your outdoor space without unwanted noise.

Small, but mighty

Central-Moov’s compact, side discharge condenser is up to 40% smaller than traditional heat pumps. The smaller units offer greater flexibility for installation and a more aesthetically pleasing finished look.

Year-round comfort

Sub-zero temperatures and inclement weather are no match for Central-Moov’s power packed condenser. The indoor unit accepts the factory optional electric resistance heat banks ranging in sizes from 5 to 25 kilowatts depending on the model.

Innovative Inverter technology

Central-Moov heat pumps incorporate the latest innovation in Inverter drive technology which saves energy by reducing the number of compressor stops and starts. The modulation by 1% increments up to 100% capacity efficiently maintains the set temperature. This innovative technology ensures maximum comfort with maximum energy efficiency.

A Perfect Match

Enjoy optimum comfort and performance by matching the Central-Moov heat pump to the Moov-Air FMA series air handler. When paired together, realise the benefit of proven cold climate heating performance, factory matched AHRI ratings and a complete system warranty coverage.

Retrofit Flexibility

Now enjoy the Central-Moov heat pump with an existing furnace*. This is possible by matching it to the Moov-Air CUB series factory matched coil. The added benefit of benefit AHRI rated combinations that achieve Canada’s toughest standards and meets the NRCan Greener Homes Grant ccASHP eligibility list.

* Not all furnaces should be retrofitted. The furnace age and type of blower must be considered. It is recommended that the blower be equipped with an energy efficient ECM motor.

DOWNLOAD BROCHURE

To explore more, download the Central-Moov Series brochure.

Moovair dealers are supported by The Master Group, Canada’s largest independently Canadian owned HVAC-R distributor. Through its 70 year history, The Master Group distinguishes itself for its extensive inventory, technical expertise, and exceptional customer service.

Reliability you can count on

Built to last, Moovair heat pumps are covered by one of the best warranty programs in the industry: 10-year limited warranty on parts and compressor. Optional labor coverage of 5 and 10 years are also available.

Documents

Brochure

Cased Coil (CUB)

Brochure

Cased Coil (CUB)

View PDF

Performance Chart

Cased Coil (CUB)

Performance Chart

Cased Coil (CUB)

View PDF

Technical specifications

Heat Pump + Add-on
18-30,000 BTU
Heat Pump + Add-on
36-60,000 BTU
HEAT PUMP SYSTEM 18,000 BTU* 24,000 BTU* 30,000 BTU* 30,000 BTU*
Indoor model CUB24HAC20BWT7A CUB24HAC20BWT7A CUB36HAC20BWT7A CUB36HAC20CWT7A
Outdoor model DMA18HOS20230E7 DMA24HOS20230E7 DMA30HOS20230E7 DMA30HOS20230E7
HEAT+ Technology Yes Yes Yes Yes
Power supply V/Ph/Hz 208–230/1/60 208–230/1/60 208–230/1/60 208–230/1/60
Cooling Capacity BTU/h (min-max) 18,000 (5,500~22,000) 24,000 (7,100~28,400) 29,000 (13,000~33,000) 30,000 (9,900~35,000)
EER2 11.7 10.7 10.0 10.5
SEER2 16.1 16.5 15.2 15.5
Heating Capacity BTU/h (min-max) 19,000 (5,900~23,600) 25,000 (8,500~28,000) 31,000 (8,000~34,000) 33,000 (9,000~37,000)
COP W/W 3.35 3.32 3.18 3.5
HSPF2 Region 5 (Region 4) 7.8 (9.5) 7.7 (9.5) 6.6 (8.5) 7.7 (9.7)
Max. fuse (A) 20 35 35 35
Compressor type Twin rotary Twin rotary Rotary Rotary
Indoor unit Width x Depth x Height mm 445×533×457 445×533×457 445×533×599 533×533×609
Width x Depth x Height in 17.52×20.98×17.99 17.52×20.98×17.99 17.52×20.98×23.58 20.98×20.98×23.98
Net/Gross weight kg 19.4/23.6 19.4/23.6 27.3/31.3 30.2/35
Net/Gross weight lbs 42.77/52.03 42.77/52.03 60.19/69.00 66.58/77.16
Outdoor fan motor Number of fans 1 1 1 1
Speed r/min 800/700/580 950/700/500/400 950/900/500 950/900/500
Outdoor noise level dB(A) 57 63.5 62 62
Outdoor unit Width x Depth x Height mm 890×342×673 946×410×810 946×410×810 946×410×810
Width x Depth x Height in 35.04×13.46×26.50 37.24×16.14×31.89 37.24×16.14×31.89 37.24×16.14×31.89
Net/Gross weight kg 46.7/49.8 62/66 72.5/77 72.5/77
Net/Gross weight lbs 102.95/109.79 136.69/145.50 159.83/169.75 159.83/169.75
Refrigerant precharge in 25 25 25 25
Refrigerant piping Liquid side, Gas side in 9.52/19 (3/8 / 3/4) 9.52/19 (3/8 / 3/4) 9.52/19 (3/8 / 3/4) 9.52/19 (3/8 / 3/4)
Max. refrigerant pipe length m (ft) 30 (98.42) 50 (164.04) 50 (164.04) 50 (164.04)
Max. elevation dif. m (ft) 20 (65.62) 20 (65,62) 25 (98,42) 25 (98,42)
Thermostat type Wired control Wired control Wired control Wired control
Outdoor temperature operating range Outdoor T° cooling °C/ºF -15~50 / 5~122 -15~50 / 5~122 -15~50 / 5~122 -15~50 / 5~122
Outdoor T° heating °C/ºF -30~24 / -22~75 -30~24 / -22~75 -30~24 / -22~75 -30~24 / -22~75
NEEP Certified Yes Yes Yes Yes
HEAT PUMP SYSTEM 36,000 BTU* 36,000 BTU* 48,000 BTU 60,000 BTU
Indoor model CUB36HAC20BWT7A CUB36HAC20CWT7A CUB48HAC20CWT7A CUB60HAC20DWT7A
Outdoor model DMA36HOS20230E7 DMA36HOS20230E7 DMA48HOS20230E7 DMA60HOS20230E7
HEAT+ Technology Yes Yes Yes Yes
Power supply V/Ph/Hz 208–230/1/60 208–230/1/60 208–230/1/60 208–230/1/60
Cooling Capacity BTU/h (min-max) 36,000 (11,700~40,000) 35,000 (11,700~40,000) 46,000 (16,500~47,000) 53,000 (13,400~54,000)
EER2 10 10 8.6 8.6
SEER2 15.5 15.2 14.3 14.5
Heating Capacity BTU/h (min-max) 38,000 (9,200~45,000) 39,000 (9,200~45,000) 51,000 (25,000~59,000) 55,000 (10,800~60,000)
COP W/W 3.18 3.18 3.04 3.08
HSPF2 Region 5 (Region 4) 7 (8.6) 8 (10) 7.5 (9) 7.1 (8.6)
Max. fuse (A) 50 50 50 50
Compressor type Rotary Rotary Rotary Rotary
Indoor unit Width x Depth x Height mm 445×533×599 533×533×609 533×533×609 622×533×711
Width x Depth x Height in 17.52×20.98×23.58 20.98×20.98×23.98 20.98×20.98×23.98 24.49×20.98×27.99
Net/Gross weight kg 27.3/31.3 30.2/35 30.2/35 39.3/44.6
Net/Gross weight lbs 60.19/69.00 66.58/77.16 66.58/77.16 86.64/98.33
Outdoor fan motor Number of fans 2 2 2 2
Speed r/min 850/750/650 850/750/650 850/750/650 850/750/650
Outdoor noise level dB(A) 63 61 64 62
Outdoor unit Width x Depth x Height mm 952×415×1333 952×415×1333 952×415×1333 952×415×1333
Width x Depth x Height in 37.48×16.34×52.48 37.48×16.34×52.48 37.48×16.34×52.48 37.48×16.34×52.48
Net/Gross weight kg 103/116 103/116 99.9/112.9 108.8/123.2
Net/Gross weight lbs 227.07/255.73 227.07/255.73 220.24/248.90 239.86/271.61
Refrigerant precharge in 25 25 25 25
Refrigerant piping Liquid side, Gas side in 9.52/19 (3/8 / 3/4) 9.52/19 (3/8 / 3/4) 9.52/19 (3/8 / 3/4) 9.52/19 (3/8 / 3/4)
Max. refrigerant pipe length m (ft) 65 (213.25) 65 (213.25) 65 (213.25) 65 (213.25)
Max. elevation dif. m (ft) 30 (98.42) 30 (98.42) 30 (98.42) 30 (98.42)
Thermostat type Wired control Wired control Wired control Wired control
Outdoor temperature operating range Outdoor T° cooling °C/ºF -15~50 / 5~122 -15~50 / 5~122 -15~50 / 5~122 -15~50 / 5~122
Outdoor T° heating °C/ºF -30~24 / -22~75 -30~24 / -22~75 -30~24 / -22~75 -30~24 / -22~75
NEEP Certified Yes Yes Yes Yes